CAPSUREEPI

DRUG ELUTING PERMANENT RIGHT VENTRICULAR (RV) OR RIGHT ATRIAL (RA) PACEMAKER ELE

This device is manufactured by MEDTRONIC, RICE CREEK MFG.

The following problems were reported about this device:

Year Description Events/year Type
2024 Over-Sensing 2 Device
2024 Low impedance 1 Device
2024 Intermittent Capture 2 Device
2024 High impedance 2 Device
2024 High Capture Threshold 1 Device
2024 Fracture 4 Device
2024 Failure to Capture 3 Device
2024 Electrical /Electronic Property Problem 2 Device
2023 Bradycardia 2 Patient
2023 Unstable Capture Threshold 1 Device
2023 Under-Sensing 1 Device
2023 Pacing Problem 3 Device
2023 Low impedance 1 Device
2023 Impedance Problem 2 Device
2023 High impedance 3 Device
2023 High Capture Threshold 1 Device
2023 Fracture 3 Device
2023 Failure to Capture 4 Device
2023 Electrical /Electronic Property Problem 1 Device
2023 Decreased Sensitivity 1 Device
2023 Adverse Event Without Identified Device or Use Problem 2 Device
2022 Bradycardia 1 Patient
2022 Under-Sensing 1 Device
2022 Over-Sensing 1 Device
2022 Material Separation 2 Device
2022 Low impedance 4 Device
2022 Impedance Problem 1 Device
2022 High impedance 3 Device
2022 High Capture Threshold 2 Device
2022 Fracture 7 Device
2022 Failure to Capture 1 Device
2022 Electrical /Electronic Property Problem 1 Device
2020 Low impedance 1 Device
2019 Unstable Capture Threshold 1 Device
2019 Under-Sensing 7 Device
2019 Signal Artifact/Noise 4 Device
2019 Positioning Problem 3 Device
2019 Pacing Problem 3 Device
2019 Over-Sensing 8 Device
2019 Low impedance 10 Device
2019 Intermittent Capture 2 Device
2019 Insufficient Information 1 Device
2019 Impedance Problem 2 Device
2019 High impedance 16 Device
2019 High Capture Threshold 8 Device
2019 Fracture 24 Device
2019 Failure to Sense 3 Device
2019 Failure to Capture 3 Device
2019 Electrical /Electronic Property Problem 1 Device
2019 Device Sensing Problem 1 Device
2019 Device Dislodged or Dislocated 1 Device
2019 Degraded 1 Device
2019 Capturing Problem 1 Device
2019 Break 8 Device
2018 Unstable Capture Threshold 3 Device
2018 Under-Sensing 3 Device
2018 Signal Artifact/Noise 3 Device
2018 Shelf Life Exceeded 1 Device
2018 Premature Discharge of Battery 1 Device
2018 Positioning Problem 2 Device
2018 Pacing Problem 1 Device
2018 Over-Sensing 9 Device
2018 Mechanical Problem 1 Device
2018 Low impedance 15 Device
2018 Intermittent Capture 1 Device
2018 Insufficient Information 1 Device
2018 Impedance Problem 9 Device
2018 High impedance 21 Device
2018 High Sensing Threshold 3 Device
2018 High Capture Threshold 20 Device
2018 Fracture 26 Device
2018 Failure to Sense 1 Device
2018 Failure to Capture 15 Device
2018 Display or Visual Feedback Problem 1 Device
2018 Device Dislodged or Dislocated 1 Device
2018 Degraded 1 Device
2018 Capturing Problem 9 Device
2018 Break 1 Device
2018 Appropriate Term/Code Not Available 4 Device
2018 Adverse Event Without Identified Device or Use Problem 2 Device
2017 Unstable Capture Threshold 8 Device
2017 Under-Sensing 3 Device
2017 Signal Artifact/Noise 8 Device
2017 Pacing Problem 3 Device
2017 Over-Sensing 6 Device
2017 Material Integrity Problem 1 Device
2017 Material Deformation 1 Device
2017 Low impedance 10 Device
2017 Intermittent Capture 2 Device
2017 Impedance Problem 5 Device
2017 High impedance 36 Device
2017 High Capture Threshold 32 Device
2017 Fracture 45 Device
2017 Failure to Sense 1 Device
2017 Failure to Capture 13 Device
2017 Device Sensing Problem 1 Device
2017 Device Operates Differently Than Expected 1 Device
2017 Device Contamination with Body Fluid 1 Device
2017 Decreased Sensitivity 1 Device
2017 Capturing Problem 5 Device
2017 Break 9 Device
2017 Appropriate Term/Code Not Available 4 Device
2017 Adverse Event Without Identified Device or Use Problem 1 Device
2016 Undesired Nerve Stimulation 1 Patient
2016 Dizziness 1 Patient
2016 Device Overstimulation of Tissue 1 Patient
2016 Unstable Capture Threshold 4 Device
2016 Signal Artifact/Noise 1 Device
2016 Pacing Problem 1 Device
2016 Over-Sensing 2 Device
2016 Mechanical Problem 1 Device
2016 Low impedance 5 Device
2016 Loose or Intermittent Connection 1 Device
2016 Impedance Problem 10 Device
2016 High impedance 22 Device
2016 High Sensing Threshold 1 Device
2016 High Capture Threshold 20 Device
2016 Fracture 20 Device
2016 Failure to Capture 18 Device
2016 Device Sensing Problem 3 Device
2016 Device Dislodged or Dislocated 1 Device
2016 Cut In Material 1 Device
2016 Connection Problem 1 Device
2016 Capturing Problem 9 Device
2016 Appropriate Term/Code Not Available 2 Device
2016 Adverse Event Without Identified Device or Use Problem 3 Device
2015 Signal Artifact/Noise 1 Device
2015 Low impedance 1 Device
2015 Intermittent Capture 1 Device
2015 Impedance Problem 2 Device
2015 High impedance 5 Device
2015 High Capture Threshold 6 Device
2015 Fracture 8 Device
2015 Failure to Capture 4 Device
2014 Unstable Capture Threshold 1 Device
2014 Stretched 1 Device
2014 Signal Artifact/Noise 1 Device
2014 Pocket Stimulation 1 Device
2014 Over-Sensing 7 Device
2014 Material Deformation 1 Device
2014 Low impedance 9 Device
2014 Impedance Problem 1 Device
2014 High impedance 19 Device
2014 High Sensing Threshold 1 Device
2014 High Capture Threshold 15 Device
2014 Fracture 23 Device
2014 Failure to Capture 15 Device
2014 Device Sensing Problem 2 Device
2014 Device Dislodged or Dislocated 1 Device
2014 Capturing Problem 1 Device
2014 Appropriate Term/Code Not Available 1 Device
2014 Adverse Event Without Identified Device or Use Problem 3 Device
2013 Insufficient Information 1 Patient
2013 Under-Sensing 1 Device
2013 Shelf Life Exceeded 1 Device
2013 Over-Sensing 1 Device
2013 Mechanical Problem 1 Device
2013 Low impedance 2 Device
2013 Impedance Problem 1 Device
2013 High impedance 4 Device
2013 High Capture Threshold 1 Device
2013 Fracture 4 Device
2013 Failure to Sense 1 Device
2013 Failure to Capture 3 Device
2013 Device Sensing Problem 1 Device
2013 Break 1 Device
2012 High impedance 1 Device
2012 High Capture Threshold 2 Device
2012 Fracture 1 Device
2012 Failure to Capture 1 Device
2011 Fracture 1 Device
2009 Unstable Capture Threshold 2 Device
2009 Positioning Problem 1 Device
2009 Low impedance 2 Device
2009 Intermittent Capture 2 Device
2009 Fracture 2 Device
2009 Failure to Capture 2 Device
2009 Break 2 Device
2009 Adverse Event Without Identified Device or Use Problem 2 Device
2008 Fracture 1 Device
2007 Signal Artifact/Noise 1 Device
2007 Fracture 1 Device
2006 Adverse Event Without Identified Device or Use Problem 1 Device
2003 Fracture 1 Device