COLONOVIDEOSCOPE
This device is manufactured by AIZU OLYMPUS CO.
The following problems were reported about this device:
Year | Description | Events/year | Type |
---|---|---|---|
2024 | No Display/Image | 5 | Device |
2024 | Microbial Contamination of Device | 2 | Device |
2024 | Mechanical Problem | 1 | Device |
2024 | Improper or Incorrect Procedure or Method | 1 | Device |
2024 | Image Display Error/Artifact | 1 | Device |
2024 | Failure to Clean Adequately | 251 | Device |
2024 | Device Reprocessing Problem | 11 | Device |
2024 | Corroded | 1 | Device |
2024 | Connection Problem | 1 | Device |
2024 | Communication or Transmission Problem | 72 | Device |
2023 | Hemorrhage/Blood Loss/Bleeding | 2 | Patient |
2023 | Bowel Perforation | 2 | Patient |
2023 | Restricted Flow rate | 1 | Device |
2023 | Poor Quality Image | 2 | Device |
2023 | Particulates | 1 | Device |
2023 | Output Problem | 1 | Device |
2023 | Obstruction of Flow | 3 | Device |
2023 | No Display/Image | 29 | Device |
2023 | Moisture Damage | 2 | Device |
2023 | Microbial Contamination of Device | 9 | Device |
2023 | Mechanical Problem | 1 | Device |
2023 | Intermittent Continuity | 2 | Device |
2023 | Incomplete or Inadequate Connection | 2 | Device |
2023 | Image Display Error/Artifact | 2 | Device |
2023 | Fluid/Blood Leak | 1 | Device |
2023 | Failure to Clean Adequately | 201 | Device |
2023 | Electrical Shorting | 1 | Device |
2023 | Electrical /Electronic Property Problem | 5 | Device |
2023 | Display or Visual Feedback Problem | 12 | Device |
2023 | Device Reprocessing Problem | 65 | Device |
2023 | Device Handling Problem | 1 | Device |
2023 | Device Contamination with Chemical or Other Material | 4 | Device |
2023 | Corroded | 2 | Device |
2023 | Contamination /Decontamination Problem | 5 | Device |
2023 | Contamination | 27 | Device |
2023 | Connection Problem | 1 | Device |
2023 | Component or Accessory Incompatibility | 1 | Device |
2023 | Component Incompatible | 2 | Device |
2023 | Complete Blockage | 3 | Device |
2023 | Communication or Transmission Problem | 105 | Device |
2023 | Break | 1 | Device |
2023 | Adverse Event Without Identified Device or Use Problem | 2 | Device |
2022 | Unspecified Hepatic or Biliary Problem | 1 | Patient |
2022 | Perforation | 1 | Patient |
2022 | Hemorrhage/Blood Loss/Bleeding | 1 | Patient |
2022 | Residue After Decontamination | 1 | Device |
2022 | Output Problem | 6 | Device |
2022 | No Display/Image | 23 | Device |
2022 | Moisture Damage | 2 | Device |
2022 | Microbial Contamination of Device | 6 | Device |
2022 | Intermittent Continuity | 2 | Device |
2022 | Incomplete or Inadequate Connection | 8 | Device |
2022 | Image Display Error/Artifact | 3 | Device |
2022 | Failure to Clean Adequately | 33 | Device |
2022 | Electrical Power Problem | 1 | Device |
2022 | Electrical /Electronic Property Problem | 1 | Device |
2022 | Display or Visual Feedback Problem | 25 | Device |
2022 | Device Reprocessing Problem | 11 | Device |
2022 | Device Contamination with Chemical or Other Material | 1 | Device |
2022 | Device Contamination with Body Fluid | 1 | Device |
2022 | Detachment of Device or Device Component | 1 | Device |
2022 | Contamination /Decontamination Problem | 8 | Device |
2022 | Contamination | 13 | Device |
2022 | Communication or Transmission Problem | 31 | Device |
2022 | Break | 1 | Device |
2022 | Adverse Event Without Identified Device or Use Problem | 1 | Device |
2021 | Poor Quality Image | 1 | Device |
2021 | No Display/Image | 3 | Device |
2021 | Image Display Error/Artifact | 1 | Device |
2021 | Display or Visual Feedback Problem | 2 | Device |
2021 | Connection Problem | 1 | Device |